New Energy Drive Motor Stator Winding Encapsulation Process

For stator winding encapsulation, as the drive motors used in new energy vehicles are evolving toward lighter, more compact designs with higher power density, and as their operating environments become increasingly harsh, higher thermal management and protection requirements are being imposed on these motors; consequently, the temperature rise of the drive motor has become a critical factor determining whether the motor can operate under continuous load for extended periods. If the heat generated by the motor during operation is not dissipated promptly, it can lead to an excessive temperature rise, which accelerates the aging of the insulation materials, reduces the motor’s service life, or even cause demagnetization of magnetic materials such as NdFeB. Therefore, temperature rise (or, more precisely, heat dissipation) is a particularly important performance indicator for drive motors in new energy vehicles.

The stator windings generate heat due to copper loss within the winding chamber; this heat is transferred to the stator core and the air (the air within the slot insulation) through thermal conduction and convection via the slot insulation and the winding surface. The encapsulation process using the thermally conductive epoxy compound JOME3113 not only eliminates the air gap within the stator winding insulation slots but also establishes a thermal path between the stator and the motor housing.

Engineering Category Reference: Explore thermally conductive potting compounds, epoxy potting compounds, and thermally conductive adhesives for EV drive motor stators.

1. The relationship between thermal conductivity, heat dissipation performance, and power increase.

Using high thermal conductivity encapsulant to establish a thermal path between the stator and the housing to enhance the overall heat dissipation performance of the motor is a feasible approach. However, no specific studies have yet been conducted to demonstrate the relationship between the thermal conductivity of the encapsulant and the increase in motor power rating.

When the thermal conductivity of the JOME3113A/B thermal encapsulant is adjusted to approximately 1.5 W/(m·K), the temperature rise of the newly manufactured electric vehicle motor after encapsulation is approximately 15–20°C lower than that of a motor manufactured using the VPI impregnation process; this result is quite significant. 2. The motor performs suboptimally under high-temperature operating conditions after the stator windings have been fully encapsulated.

Generally, the nominal operating range of a new energy vehicle motor

Temperature range: -40°C to 180°C.

3. Comprehensive consideration of thermal conductivity and cost

The most effective way to enhance the thermal conductivity of potting compound is to add an adequate amount of thermal conductive fillers; these fillers create thermal conduction pathways within the epoxy resin matrix, thereby improving the overall thermal conductivity of the potting compound.

However, thermal conductive fillers are generally more expensive than conventional inorganic fillers. The higher the amount of thermal conductive filler added, the better the thermal conductivity of the potting compound, but the cost increases accordingly. Currently, in various other applications, thermal conductive potting compounds with a thermal conductivity ranging from 1.0 to 1.5 are most commonly selected for motor applications.

  • Encapsulation process compatibility For the drive motors of new energy vehicles, vacuum casting combined with heating curing is considered the more ideal approach; therefore, when designing the curing process for the JOME3113A/B thermal conductive encapsulant, the following factors should be primarily taken into account:

The crosslinking density of heat-curing epoxy systems is generally higher than that of room-temperature amine-based systems, resulting in superior performance under high-temperature operating conditions;

The heating and curing system allows for the adjustment of the viscosity of individual components during the initial curing stage by means of temperature control, thereby facilitating the proper wetting of the mixture onto the stator windings.

5. The issue of motor weight increase caused by thermal encapsulant

A large number of experiments have demonstrated that epoxy resin-based high-thermal-conductivity encapsulant adhesives generally exhibit a relatively high specific gravity; however, the specific gravity varies depending on the choice of thermal conductive fillers. Typically, for adhesives with a thermal conductivity of approximately 1.0, the specific gravity ranges between 1.8 and 1.9; whereas for adhesives with a thermal conductivity of approximately 1.2, the specific gravity can range between 2.1 and 2.3.

In the cost analysis of thermal conductive encapsulants, the thermal conductive filler often accounts for the largest portion of the total cost; the cost of an encapsulant with a thermal conductivity of 3.0 is typically several times higher than that of an encapsulant with a thermal conductivity of 1.0!

For conventional motors, a value of 0.8–1.2 W/m·K is sufficient; for motors with high power density, the target ranges from 1.5–2.0 W/m·K or higher; only for specialized motors does the pursuit of 3.0 W/m·K or even higher values become relevant.

Stator Winding Encapsulation: Vacuuming Before and After Adhesive Application

1: Stator winding encapsulation: degassing before potting (static degassing)

After mixing the glue, transfer it into the vacuum tank and evacuate it for 5–15 minutes; once the liquid surface stops producing bubbles, remove it and fill the container. The advantage is that the process is simple and controllable, eliminating concerns about the glue bubbling or exploding inside the stator. However, there is a clear drawback: during filling, some new bubbles may still be introduced, as the operation is performed under atmospheric pressure.

2: Apply adhesive and then perform vacuuming.

After the adhesive is applied to the stator, the workpiece is simultaneously placed into the vacuum chamber for evacuation over a period of 3–10 minutes to forcibly remove any air trapped within the iron core slots. The advantage of this method is that it effectively clears all dead-air bubbles from the gaps between the coils. The disadvantage is the narrow time window: the adhesive must be in a flowing state for degassing to occur; if evacuation is performed once the adhesive’s viscosity has increased, it will be ineffective.

Recommendation: Before filling with adhesive, perform a degassing cycle (to remove any bubbles introduced during mixing); after filling the stator, place it in a vacuum chamber for a vacuuming cycle (do not fill to capacity – leave a 20–30% margin to prevent adhesive leakage!).

Trace resin flow through the winding geometry

For stator winding encapsulation, a level resin surface does not reveal whether material has reached the spaces between the windings and the surrounding structure. Map the intended filling route and identify where air can escape as resin advances. Why approve the filling operation from its visible top surface when concealed pockets are part of the thermal and electrical assessment? Trial the process on representative winding geometry and inspect otherwise hidden regions. Follow formulation-specific mixing and degassing instructions rather than applying an improvised vacuum sequence to every resin. It’s necessary to check cure heat and material condition in the actual filled stator, since a thin sample does not reproduce the same containment. The potting and encapsulating compound category can support selection based on the flow path, winding materials and proposed cure route.

Check insulation and thermal behavior after processing

The assessment of stator winding encapsulation should include the winding insulation system, terminals and features that must remain clear. Inspect compatibility with wire enamel, slot insulation and nearby finishes before extending a successful resin trial to a complete stator. After cure, examine coverage and component alignment, then perform the relevant electrical and thermal checks under defined conditions. Repeat appropriate checks following environmental or mechanical conditioning associated with service. Cracking, separation from a housing and damage to an insulation layer are different findings; record their location instead of treating them as a single potting failure. Thermal behavior depends on the installed path from the winding toward the cooling structure, so a bulk material property cannot describe the entire assembly. The thermally conductive adhesive material category supports the heat-transfer discussion, with electrical requirements assessed separately.

Selection of the right grade from the potting and encapsulating compound range usually starts with drawings and service conditions. The companion piece on The application of high performance adhesives in sits alongside this guide, the Shanghai JOME Industrial Co. product line lists every family, and the ask JOME for grade selection help handles enquiries.

Verified JOME Engineering Grades & Specification Cross-Reference

To qualify an industrial-grade adhesive, potting compound, or thermal interface material for this application, compare verified Shanghai Jome Industrial Co., Ltd. (JOME) formulations below or explore our primary category hubs: Anaerobic Threadlockers & Retaining Adhesives and Industrial Structural Adhesives.

JOME Grade / SKUPolymer Chemistry & CureKey Verified SpecificationPrimary Industrial Application
JOM 3107Anaerobic Magnet Structural Bonding AdhesiveHigh impact & centrifugal shear (>20 MPa) | +150°C ratedServo motor, traction motor & humanoid robot rotor magnet bonding
JOME 1767 / JOME 2029A/B1K Heat-Cure & 2K High-Temp Motor EpoxyContinuous service up to +180–200°C | High Tg & chemical resistanceHigh-speed turbine rotors, rare-earth & ferrite magnet bonding
JOM 638High-Strength Cylindrical Bearing Retaining CompoundFills 0.05–0.25 mm radial clearances | Prevents fretting wearMotor shafts, harmonic drive bearings, gears, bushings & sleeves
JOM 263/277 & JOM 204/93Liquid Anaerobic & Microcapsule Pre-Coated ThreadlockersBreakaway torque 20–42 N·m | Oil-tolerant & dry-to-touch filmChassis bolts, robot joint fasteners, mass pre-coated screws

Interactive Engineering Tools: Master Substrate & Thermal Cross-Reference Chart · Potting Volume, Mix Ratio & ΔT Calculator · Industrial Adhesive Manufacturer Comparison

Work From Whatever You Have · Custom Formulation & Free Trial Samples

Need Technical Data Sheets (TDS) or Trial Samples for Line Qualification?

Share your substrate pair, operating temperature, or target cycle time—only Email and Application / Part Code are required. Our R&D engineers reply within 24 hours.

Matched JOME Industrial Formulations: For production bonding, potting, and sealing qualification in this application, evaluate 204 Microcapsule pre-coated threaded locking adhesive, 263 、277 Thread Locking Adhesive Prevents Bolts From Coming Loose, 638 Cylindrical metal bearing adhesive for fixation, and 567 Anaerobic metal pipe thread sealant (ISO 9001:2015 and CTI RoHS 2.0 verified; free engineering samples shipped via UPS freight collect).

Frequently Asked Engineering Questions

Which JOME adhesive or potting grades are recommended for new energy drive motor stator winding encapsulation process?

Depending on substrate pair, continuous operating temperature, and curing line constraints, Shanghai Jome Industrial Co., Ltd. (JOME) recommends evaluating JOM 3107, JOME 1767 / JOME 2029A/B, and JOM 638. Review our full specification table on this page or request a customized formulation sample.

Can JOME customize viscosity, cure speed, or thermal conductivity for our automated production line?

Yes. JOME's Shanghai RandD laboratory customizes A/B mix viscosity, thixotropic index, pot life, Shore hardness, and thermal filler loading (0.75 to 25.0 W/m·K) to match your dispensing equipment and environmental test standards.

Related Industrial Adhesive Products & Engineering Guides

Introduction to Adhesives: Do You Really Understand Them All? — Adhesives Knowledge (Part 2) · A Comprehensive Guide to Structural Adhesives · Do you truly understand adhesives? An In-depth Guide to Adhesives Knowledge · What adhesive should be used for PE coating? · What adhesive should be used for PI-coated copper foil? · Which adhesive should be used to bond metal film materials? · Which adhesives are suitable for forming a film? · Adhesive for optical communications: specialty resin · Technical Analysis: Synthesis Principles and Key Applications of UV-High-Refractive-Index Resin and Monomers · A Brief Analysis of Dual-Curing UV Resins: Types and Applications · Adhesive Solutions for Public Transportation · Introduction to Adhesive Solutions for the Aerospace Industry · Introduction to adhesive and lubricant solutions for bearings and gears · The adhesive solution used in the bonding process (Die Attach adhesive) · Adhesive solution for electronic equipment control systems of new energy vehicles · Introduction to the Glue Solution for PCB Boards · Five key applications of adhesives in the photovoltaic industry · Application solutions for adhesives used in aviation and ships

For Immediate Assistance, Please Contact us Now!

InquiryWhatsApp